ER
0 - 16777215
#AER
*AER5
Error ReadQuery Only
- Returns the current Encoder Error value. If the product
of Encoder Lines and Encoder mode is larger than the
product of Motor Steps and Step Resolution, then the
error is in Encoder Counts. Otherwise it is in Steps.
MF
-
#AMF200
Sets Motor
Fullsteps to
200
Motor Fullsteps (per revolution)Command or Query
Default = 200
Reads or sets the number of Fullsteps per motor
revolution, i.e. A 1.8° motor will have a Fullstep count of
200.
Motion Profile Commands
Graph 8.1
SV: Start Velocitythe very first step it takes begins with the start velocity value (must be ≥ MV)
MV: Minimum Velocity
AC: Acceleration (and deceleration)
VL: Velocity Limitsets the max speed the motor will rotate during a VM, PM or DV move command
VM: Velocity Mode rotates the motor at a fixed speed for continuous motion (use this to jog 1 direction only)
DV: Direction Velocityrotates the motor at a fixed speed for continuous motion, but allows the motor to
change direction of rotation smoothly. Use this command rather than the VM command if jogging CW and CCW
AC
SV
Velocity
Time
VL
AC
DV-
MV
VM
DV+
RMS Technologies Page 23 Version 1.01
R325PE Single Axis Closed loop Driver/Indexer Manual 5/29/2013
Zobrazit stránku 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 29 30

Komentáře k této Příručce

Žádné komentáře

SEVERIN AS3950 manuels

Manuels d'utilisation et guides de l'utilisateur pour Trancheurs SEVERIN AS3950.
Nous fournissons des manuels en pdf 1 SEVERIN AS3950 à télécharger gratuitement par type de document : Mode d'emploi






Plus de produits et de manuels pour Trancheurs SEVERIN

Modèles Type de document
AS 9621 Mode d'emploi       Severin AS 9621, 46 pages
AS 3948 Manuel   Severin AS 3948, 4 pages
AS 3947 Mode d'emploi      Severin AS 3947, 54 pages